SIC OpenIR
Simplified design for solution anode glow discharge atomic emission spectrometry device for highly sensitive detection of Ag, Bi, Cd, Hg, Pb, Tl, and Zn
Yuan, ML; Peng, XX; Ge, F; Li, Q; Wang, K; Yu, DG; Wang, Z
2020-06-01
Source PublicationMICROCHEMICAL JOURNAL
ISSN0026-265X
SubtypeArticle
AbstractHerein, we propose a simplified design for a solution anode glow discharge-atomic emission spectrometry (SAGD-AES) device for determination of Ag, Bi, Cd, Hg, Pb, Tl, and Zn concentrations in solutions with high sensitivity. Using a Ti rod as the cathode, the need for a cooling device and noble gas environment was eliminated, which would enable the miniaturization of the device in the future. Moreover, the quartz tube in the device was directly connected to the graphite rod to eliminate the need to maintain a constant sample solution level in the device during discharge. A thorough parametric evaluation of the proposed SAGD-AES for heavy metal determination was performed. Our proposed SAGD-AES device achieved detection limits of 0.03, 1.98, 0.07, 1.7, 1.35, 0.02, and 0.12 mu g L-1 for Ag, Bi, Cd, Hg, Pb, Tl, and Zn, respectively, with the corresponding relative standard deviations for analyte concentrations of 10 mu g L-1 (Ag, Cd, Tl, Zn) and 200 mu g L-1 (Bi, Hg, Pb) being <5%. The accuracy of the proposed SAGD-AES design was experimentally verified by the determination of heavy metal concentrations in a simulated natural water sample (GBW08607) and in waste laboratory liquid. The results obtained using our device were in good agreement with those obtained using inductively coupled plasma mass spectrometry.
DOI10.1016/j.microc.2020.104785
WOS KeywordVAPOR GENERATION ; ELEMENTAL ANALYSIS ; LIQUID CATHODE ; INDUCED PLASMA ; WATER SAMPLES ; CADMIUM ; REMEDIATION ; SURFACTANTS ; IMPROVEMENT ; CONTACT
Language英语
WOS Research AreaChemistry
PublisherELSEVIER
Citation statistics
Cited Times:2[WOS]   [WOS Record]     [Related Records in WOS]
Document Type期刊论文
Identifierhttp://ir.sic.ac.cn/handle/331005/28030
Collection中国科学院上海硅酸盐研究所
Recommended Citation
GB/T 7714
Yuan, ML,Peng, XX,Ge, F,et al. Simplified design for solution anode glow discharge atomic emission spectrometry device for highly sensitive detection of Ag, Bi, Cd, Hg, Pb, Tl, and Zn[J]. MICROCHEMICAL JOURNAL,2020.
APA Yuan, ML.,Peng, XX.,Ge, F.,Li, Q.,Wang, K.,...&Wang, Z.(2020).Simplified design for solution anode glow discharge atomic emission spectrometry device for highly sensitive detection of Ag, Bi, Cd, Hg, Pb, Tl, and Zn.MICROCHEMICAL JOURNAL.
MLA Yuan, ML,et al."Simplified design for solution anode glow discharge atomic emission spectrometry device for highly sensitive detection of Ag, Bi, Cd, Hg, Pb, Tl, and Zn".MICROCHEMICAL JOURNAL (2020).
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Yuan, ML]'s Articles
[Peng, XX]'s Articles
[Ge, F]'s Articles
Baidu academic
Similar articles in Baidu academic
[Yuan, ML]'s Articles
[Peng, XX]'s Articles
[Ge, F]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Yuan, ML]'s Articles
[Peng, XX]'s Articles
[Ge, F]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.