SIC OpenIR
Larmor Precession: Observation and Utilization for Boosting the Signal Intensity of Radio Frequency Glow Discharge Mass Spectrometry
Wang, ML; Qian, R; Zhuo, SJ; Chen, Q; Li, ZQ; Zhao, B
2020-07-21
Source PublicationANALYTICAL CHEMISTRY
ISSN0003-2700
Issue14Pages:9528
SubtypeArticle
AbstractA novel magnet array system was constructed to use Larmor precession for boosting the signal intensity of rf-GD-MS. The enhancement mechanism with four magnet array devices of a single-block magnet and 2 X 2, 3 X 2, and 3 X 4 magnet arrays was simulated and studied by COMSOL Multiphysics Software 5.4.0 (COMSOL) to determine if the electrons in the discharge plasma could perform Larmor precession along the direction perpendicular to the magnetic field. Induced by Larmor precession, inelastic collisions between the primary electrons and the sample produced numerous secondary electrons and further improved the ionization efficiency. Moreover, the fuzzy synthetic evaluation result predicted that the device with a 3X 2 magnet array would display the greatest enhancement effect among the four devices. On the basis of these theoretical studies, a magnet array system with four magnet array devices was fabricated and utilized for studies of two scintillation crystals BGO and PWO. The observations indicated that the signal intensities obtained for Bi-209 and Pb-208 with the magnet array system were 630-3600 times of that obtained without a magnet and were enhanced by a factor of 1.5-2.8 compared with a previously reported stacked magnetic device. Two NIST samples were used to validate the method, and the results suggested that relative errors were less than 10%, and the lowest detection limit for the 3 X 2 magnet array could reach 0.0032 mu g.g(-1). Furthermore, the magnet array enhancement system with Larmor precession offers an efficient and sensitive approach for direct analysis of nonconducting materials.
DOI10.1021/acs.analchem.0c00588
WOS KeywordQUANTIFICATION ; ENHANCEMENT ; SURFACE ; PLASMA
Language英语
WOS Research AreaChemistry
PublisherAMER CHEMICAL SOC
Citation statistics
Document Type期刊论文
Identifierhttp://ir.sic.ac.cn/handle/331005/27896
Collection中国科学院上海硅酸盐研究所
Recommended Citation
GB/T 7714
Wang, ML,Qian, R,Zhuo, SJ,et al. Larmor Precession: Observation and Utilization for Boosting the Signal Intensity of Radio Frequency Glow Discharge Mass Spectrometry[J]. ANALYTICAL CHEMISTRY,2020(14):9528.
APA Wang, ML,Qian, R,Zhuo, SJ,Chen, Q,Li, ZQ,&Zhao, B.(2020).Larmor Precession: Observation and Utilization for Boosting the Signal Intensity of Radio Frequency Glow Discharge Mass Spectrometry.ANALYTICAL CHEMISTRY(14),9528.
MLA Wang, ML,et al."Larmor Precession: Observation and Utilization for Boosting the Signal Intensity of Radio Frequency Glow Discharge Mass Spectrometry".ANALYTICAL CHEMISTRY .14(2020):9528.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Wang, ML]'s Articles
[Qian, R]'s Articles
[Zhuo, SJ]'s Articles
Baidu academic
Similar articles in Baidu academic
[Wang, ML]'s Articles
[Qian, R]'s Articles
[Zhuo, SJ]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Wang, ML]'s Articles
[Qian, R]'s Articles
[Zhuo, SJ]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.