SIC OpenIR
FEM simulation and comparison of PMN-PT single crystals based phased array ultrasonic transducer by alternating current poling and direct current poling
Zhang, Z; Xu, JL; Liu, SX; Xiao, JJ; Wang, X; Liang, Z; Luo, HS
2020-12-01
Source PublicationULTRASONICS
ISSN0041-624X
SubtypeArticle
AbstractThe Finite element modeling (FEM) simulation and comparison of electroacoustic properties for alternating current poling (ACP) phased arrays and direct current poling (DCP) phased arrays were investigated. The simulated electrical impedance reveals that the effective working bandwidth of ACP phased arrays is wider than that of DCP phased arrays as a whole. Besides, the ACP phased arrays have a higher effective electromechanical coupling coefficient k(eff) compared to DCP arrays, which indicates that higher electromechanical conversion capacity is obtained. The average value of the ratio of longitudinal displacement R-d(isp) for ACP phased arrays is larger than that of DCP arrays, indicating that the longitudinal transmission efficiency of acoustic energy can be enhanced by using the ACP method. The simulation results of crosstalk are consistent with the results of vibration modal analysis. The coupling effect of transverse vibration for ACP phased arrays is weaker than that of DCP arrays, leading to reduce the interaction between the adjacent elements. The crosstalk of the ACP arrays is -11.87 dB, 0.91 dB lower than that of DCP arrays. The pulse-echo response of ACP phased arrays is 7.2% broader - 6 dB bandwidth, 0.79 dB higher relative sensitivity compared to the DCP phased arrays, which prove that the longitudinal resolution and penetration depth of the ultrasonic imaging can be improved by using the ACP arrays. Besides, the consequences of the beam profile illustrate that the maximum acoustic pressure of ACP arrays is 13.8% higher than that of DCP arrays and the directivity of ACP array is slightly better than that of DCP arrays.
DOI10.1016/j.ultras.2020.106175
WOS KeywordLINEAR-ARRAY ; IMAGING-SYSTEM ; HIGH-FREQUENCY ; DESIGN ; FABRICATION
Language英语
WOS Research AreaAcoustics ; Radiology, Nuclear Medicine & Medical Imaging
PublisherELSEVIER
Citation statistics
Document Type期刊论文
Identifierhttp://ir.sic.ac.cn/handle/331005/27596
Collection中国科学院上海硅酸盐研究所
Recommended Citation
GB/T 7714
Zhang, Z,Xu, JL,Liu, SX,et al. FEM simulation and comparison of PMN-PT single crystals based phased array ultrasonic transducer by alternating current poling and direct current poling[J]. ULTRASONICS,2020.
APA Zhang, Z.,Xu, JL.,Liu, SX.,Xiao, JJ.,Wang, X.,...&Luo, HS.(2020).FEM simulation and comparison of PMN-PT single crystals based phased array ultrasonic transducer by alternating current poling and direct current poling.ULTRASONICS.
MLA Zhang, Z,et al."FEM simulation and comparison of PMN-PT single crystals based phased array ultrasonic transducer by alternating current poling and direct current poling".ULTRASONICS (2020).
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Zhang, Z]'s Articles
[Xu, JL]'s Articles
[Liu, SX]'s Articles
Baidu academic
Similar articles in Baidu academic
[Zhang, Z]'s Articles
[Xu, JL]'s Articles
[Liu, SX]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Zhang, Z]'s Articles
[Xu, JL]'s Articles
[Liu, SX]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.